User Tools

Site Tools


supported_hardware:ups

This is an old revision of the document!


UPS: Uninterruptible Power Supply Plugin

The UPS plugin provides a connection between XTension and a UPS that is compatible with the built in OSX support for such devices. If you see a battery level in the system for a UPS connected via USB then the same UPS will be compatible with the UPS plugin for XTension. Build 830 of XTension adds the reporting of disk drive space to this plugin too.

The UPS plugin is included in demo mode in the release version of XTension, only a plugin serial number purchased from sentman.com is necessary to unlock it for full time functionality. The demo mode will run for only 1 hour before turning itself off during any given session with XTension. So you can verify that it works with your UPS device before purchasing.

By providing a pseudo unit associated with AC Power availability you can take action in response to a power failure or power restoration, even a short duration one which may require that problem appliance modules be reset as they can turn on if the power flickers. The time to empty value can be used to give warnings of immanent shutdown.

For more information on dealing with UPS's and power failures with the Macintosh and XTension please see Dealing With Power Failures

Using UPS Monitor with XTension

Create a new interface in XTensions preferences and select “ups” as the device type. No port selections or other setup is required, just give it a more descriptive name. In order to make available all the information that the plugin can provide you'll need to create 6 units. Assign them to the ups interface you created earlier and give them the following address strings:

  • AC Power Available (address: “AC”, not dimmable)
  • Capacity in percent of the battery (address: “CAPACITY”, dimmable)
  • Max Capacity (address: “MAXCAPACITY”, dimmable)
  • Time To Empty (address: “TIMETOEMPTY”, dimmable) approx minutes before the machine shuts down. It may display 0 if AC power is available.
  • Time To Full Charge (address: “TIMETOFULLCHARGE”, dimmable) approx minutes before the battery is recharged. If battery is fully charged it may read 0.
  • Is Charging (address: “CHARGING”, not dimmable) is the battery currently charging or not.

Monitoring Disk Space

With version 830 of XTension this plugin also sends regular updates with the percent available and k available for each mounted disk. Create a unit on this interface with the name of the disk drive as the address to receive the bytes available in k, and create another but put a “%” at the end of the disk name to receive the percent available value. Both values are always sent though you do not have to create a unit for them if you do not wish to they will always show in the log. The system may also include various other mounted file systems such as the time machine disk and volume that are dynamically created and unmounted by the system as well as other network file systems.

Running out of disk space on the server can be a major headache and cause data loss and database corruption even though XTension goes to a great deal of trouble not to corrupt itself in that case it’s not something you want to happen if you can avoid it. Sending yourself an email or other alert when this gets too low is a really good idea.

supported_hardware/ups.1325601254.txt.gz · Last modified: 2023/02/13 14:51 (external edit)